Tree 5 (filesystem)

Explanation

This page shows the content of a tree. It is essentially a list of items, each of which consist of a key and a value.

The key is shown in the boxes on the left. It is a triple of a 64-bit id, an 8-bit type, and a 64-bit offset. What each of them means depends on the tree we're in. You can search for a key id by using the search field below.

The value is summarized to the right of the key. To see the value in more detail, unfold the key by clicking on it.

Finally, to the very right, we have the logical address of the metadata node which the item is stored in.

go back to root tree
1C24Dir (54)652C2402"termite" @ 1C6225A8000
name"termite"
target key1C62 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7266,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "termite",
    },
)
show hex data
62 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 72 6D 69 74 65 
1C24Dir (54)65C9523D"tty5410v1" @ 17C725A8000
name"tty5410v1"
target key17C7 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 6087,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 9,
        dir_type: 1,
        name: "tty5410v1",
    },
)
show hex data
C7 17 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 09 00 01 74 74 79 35 34 31 30 76 31 
1C24Dir (54)678EEA32"tvi912b" @ 1C8525A8000
name"tvi912b"
target key1C85 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7301,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tvi912b",
    },
)
show hex data
85 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 76 69 39 31 32 62 
1C24Dir (54)6A4B59DA"teraterm4.97" @ 1C5B25A8000
name"teraterm4.97"
target key1C5B Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7259,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "teraterm4.97",
    },
)
show hex data
5B 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 65 72 61 74 65 72 6D 34 2E 39 37 
1C24Dir (54)6AD56562"tw52" @ 1CB625A8000
name"tw52"
target key1CB6 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7350,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 4,
        dir_type: 1,
        name: "tw52",
    },
)
show hex data
B6 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 04 00 01 74 77 35 32 
1C24Dir (54)6B32F4CD"tty5410-w" @ 16DF25A8000
name"tty5410-w"
target key16DF Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 5855,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 9,
        dir_type: 1,
        name: "tty5410-w",
    },
)
show hex data
DF 16 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 09 00 01 74 74 79 35 34 31 30 2D 77 
1C24Dir (54)6D7744EA"teken-2022" @ 1C5225A8000
name"teken-2022"
target key1C52 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7250,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "teken-2022",
    },
)
show hex data
52 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 65 6B 65 6E 2D 32 30 32 32 
1C24Dir (54)6DCEBC0D"terminator" @ 1C5C25A8000
name"terminator"
target key1C5C Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7260,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "terminator",
    },
)
show hex data
5C 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 65 72 6D 69 6E 61 74 6F 72 
1C24Dir (54)6DCFAC69"ts100-ctxt" @ 1C7B25A8000
name"ts100-ctxt"
target key1C7B Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7291,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "ts100-ctxt",
    },
)
show hex data
7B 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 73 31 30 30 2D 63 74 78 74 
1C24Dir (54)705B9D2E"teken-vt+fkeys" @ 1C5525A8000
name"teken-vt+fkeys"
target key1C55 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7253,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "teken-vt+fkeys",
    },
)
show hex data
55 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 65 6B 65 6E 2D 76 74 2B 66 6B 65 79 73 
1C24Dir (54)72AA6A92"tek4027" @ 1C3825A8000
name"tek4027"
target key1C38 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7224,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tek4027",
    },
)
show hex data
38 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 6B 34 30 32 37 
1C24Dir (54)72B181CC"tvi914" @ 1C8425A8000
name"tvi914"
target key1C84 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7300,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 6,
        dir_type: 1,
        name: "tvi914",
    },
)
show hex data
84 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 06 00 01 74 76 69 39 31 34 
1C24Dir (54)72BF445B"tvi920c-unk-vb" @ 1CA225A8000
name"tvi920c-unk-vb"
target key1CA2 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7330,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tvi920c-unk-vb",
    },
)
show hex data
A2 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 76 69 39 32 30 63 2D 75 6E 6B 2D 76 62 
1C24Dir (54)72CDDA46"ts100" @ 1C7A25A8000
name"ts100"
target key1C7A Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7290,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "ts100",
    },
)
show hex data
7A 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 73 31 30 30 
1C24Dir (54)73A73D49"tvi921" @ 1CA425A8000
name"tvi921"
target key1CA4 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7332,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 6,
        dir_type: 1,
        name: "tvi921",
    },
)
show hex data
A4 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 06 00 01 74 76 69 39 32 31 
1C24Dir (54)73BCD617"tek4012" @ 1C3125A8000
name"tek4012"
target key1C31 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7217,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tek4012",
    },
)
show hex data
31 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 6B 34 30 31 32 
1C24Dir (54)73E349D6"tvi920c-p" @ 1C9F25A8000
name"tvi920c-p"
target key1C9F Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7327,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 9,
        dir_type: 1,
        name: "tvi920c-p",
    },
)
show hex data
9F 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 09 00 01 74 76 69 39 32 30 63 2D 70 
1C24Dir (54)748CF21A"tvi950-rv-2p" @ 1CAE25A8000
name"tvi950-rv-2p"
target key1CAE Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7342,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi950-rv-2p",
    },
)
show hex data
AE 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 35 30 2D 72 76 2D 32 70 
1C24Dir (54)74D410E2"tty37" @ 1C7E25A8000
name"tty37"
target key1C7E Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7294,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "tty37",
    },
)
show hex data
7E 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 74 79 33 37 
1C24Dir (54)767B139A"tek4112-nd" @ 1C4525A8000
name"tek4112-nd"
target key1C45 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7237,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tek4112-nd",
    },
)
show hex data
45 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 65 6B 34 31 31 32 2D 6E 64 
1C24Dir (54)77B9549D"tvi920b-p-2p" @ 1C9B25A8000
name"tvi920b-p-2p"
target key1C9B Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7323,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi920b-p-2p",
    },
)
show hex data
9B 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 32 30 62 2D 70 2D 32 70 
1C24Dir (54)7840A8CB"ti745" @ 1C6325A8000
name"ti745"
target key1C63 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7267,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "ti745",
    },
)
show hex data
63 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 69 37 34 35 
1C24Dir (54)786E4E0E"tvi920c-mc" @ 1C9D25A8000
name"tvi920c-mc"
target key1C9D Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7325,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tvi920c-mc",
    },
)
show hex data
9D 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 76 69 39 32 30 63 2D 6D 63 
1C24Dir (54)78A7FF5B"tvi912b-mc-vb" @ 1C9025A8000
name"tvi912b-mc-vb"
target key1C90 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7312,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 13,
        dir_type: 1,
        name: "tvi912b-mc-vb",
    },
)
show hex data
90 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0D 00 01 74 76 69 39 31 32 62 2D 6D 63 2D 76 62 
1C24Dir (54)78BAE8FC"tty5420+nl" @ 17CA25A8000
name"tty5420+nl"
target key17CA Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 6090,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tty5420+nl",
    },
)
show hex data
CA 17 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 74 79 35 34 32 30 2B 6E 6C 
1C24Dir (54)78EA322A"t1061f" @ 1C2725A8000
name"t1061f"
target key1C27 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7207,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 6,
        dir_type: 1,
        name: "t1061f",
    },
)
show hex data
27 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 06 00 01 74 31 30 36 31 66 
1C24Dir (54)79021CAC"tvi910+" @ 1C8325A8000
name"tvi910+"
target key1C83 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7299,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tvi910+",
    },
)
show hex data
83 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 76 69 39 31 30 2B 
1C24Dir (54)7AA8B77A"tty5620" @ 16E225A8000
name"tty5620"
target key16E2 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 5858,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tty5620",
    },
)
show hex data
E2 16 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 74 79 35 36 32 30 
1C24Dir (54)7B190F49"tw52-color" @ 1CB625A8000
name"tw52-color"
target key1CB6 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7350,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tw52-color",
    },
)
show hex data
B6 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 77 35 32 2D 63 6F 6C 6F 72 
1C24Dir (54)7B7B293C"tvi920b-unk-2p" @ 1C9C25A8000
name"tvi920b-unk-2p"
target key1C9C Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7324,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tvi920b-unk-2p",
    },
)
show hex data
9C 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 76 69 39 32 30 62 2D 75 6E 6B 2D 32 70 
1C24Dir (54)7C483D7D"teken-sc" @ 1C532598000
name"teken-sc"
target key1C53 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7251,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 8,
        dir_type: 1,
        name: "teken-sc",
    },
)
show hex data
53 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 08 00 01 74 65 6B 65 6E 2D 73 63 
1C24Dir (54)7CFB8A64"tvi912b-p-2p" @ 1C8D2598000
name"tvi912b-p-2p"
target key1C8D Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7309,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi912b-p-2p",
    },
)
show hex data
8D 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 31 32 62 2D 70 2D 32 70 
1C24Dir (54)7F67FE12"ti916-220-7" @ 1C662598000
name"ti916-220-7"
target key1C66 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7270,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 11,
        dir_type: 1,
        name: "ti916-220-7",
    },
)
show hex data
66 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0B 00 01 74 69 39 31 36 2D 32 32 30 2D 37 
1C24Dir (54)7F8EFB95"teraterm-256color" @ 1C582598000
name"teraterm-256color"
target key1C58 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7256,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 17,
        dir_type: 1,
        name: "teraterm-256color",
    },
)
show hex data
58 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 11 00 01 74 65 72 61 74 65 72 6D 2D 32 35 36 63 6F 6C 6F 72 
1C24Dir (54)7FFC5459"ti_ansi" @ 1C732598000
name"ti_ansi"
target key1C73 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7283,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "ti_ansi",
    },
)
show hex data
73 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 69 5F 61 6E 73 69 
1C24Dir (54)80FBA511"tt52" @ 1C7C2598000
name"tt52"
target key1C7C Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7292,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 4,
        dir_type: 1,
        name: "tt52",
    },
)
show hex data
7C 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 04 00 01 74 74 35 32 
1C24Dir (54)80FD7004"tek4025ex" @ 16DE2598000
name"tek4025ex"
target key16DE Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 5854,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 9,
        dir_type: 1,
        name: "tek4025ex",
    },
)
show hex data
DE 16 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 09 00 01 74 65 6B 34 30 32 35 65 78 
1C24Dir (54)818EED55"tvi920b-2p" @ 1C992598000
name"tvi920b-2p"
target key1C99 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7321,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tvi920b-2p",
    },
)
show hex data
99 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 76 69 39 32 30 62 2D 32 70 
1C24Dir (54)81CCBE4A"tvi920" @ 1C842598000
name"tvi920"
target key1C84 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7300,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 6,
        dir_type: 1,
        name: "tvi920",
    },
)
show hex data
84 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 06 00 01 74 76 69 39 32 30 
1C24Dir (54)81D75514"tek4013" @ 1C322598000
name"tek4013"
target key1C32 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7218,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tek4013",
    },
)
show hex data
32 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 6B 34 30 31 33 
1C24Dir (54)83F130A2"tek4027-ex" @ 1C3C2598000
name"tek4027-ex"
target key1C3C Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7228,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tek4027-ex",
    },
)
show hex data
3C 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 65 6B 34 30 32 37 2D 65 78 
1C24Dir (54)84B7DAA3"tvi912c-p" @ 1C912598000
name"tvi912c-p"
target key1C91 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7313,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 9,
        dir_type: 1,
        name: "tvi912c-p",
    },
)
show hex data
91 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 09 00 01 74 76 69 39 31 32 63 2D 70 
1C24Dir (54)84E5C1DB"tn300" @ 1C5D2598000
name"tn300"
target key1C5D Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7261,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "tn300",
    },
)
show hex data
5D 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 6E 33 30 30 
1C24Dir (54)85E8E997"tvi912b-vb" @ 1C952598000
name"tvi912b-vb"
target key1C95 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7317,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tvi912b-vb",
    },
)
show hex data
95 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 76 69 39 31 32 62 2D 76 62 
1C24Dir (54)87182A5B"tvi912b-unk" @ 1C932598000
name"tvi912b-unk"
target key1C93 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7315,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 11,
        dir_type: 1,
        name: "tvi912b-unk",
    },
)
show hex data
93 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0B 00 01 74 76 69 39 31 32 62 2D 75 6E 6B 
1C24Dir (54)87C07464"tvi912c-unk-2p" @ 1C8E2598000
name"tvi912c-unk-2p"
target key1C8E Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7310,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tvi912c-unk-2p",
    },
)
show hex data
8E 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 76 69 39 31 32 63 2D 75 6E 6B 2D 32 70 
1C24Dir (54)8A35976C"tn1200" @ 1C5D2598000
name"tn1200"
target key1C5D Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7261,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 6,
        dir_type: 1,
        name: "tn1200",
    },
)
show hex data
5D 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 06 00 01 74 6E 31 32 30 30 
1C24Dir (54)8ABFD07D"tgtelnet" @ 1B702598000
name"tgtelnet"
target key1B70 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7024,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 8,
        dir_type: 1,
        name: "tgtelnet",
    },
)
show hex data
70 1B 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 08 00 01 74 67 74 65 6C 6E 65 74 
1C24Dir (54)8AF1E222"tmux-256color" @ 1C762598000
name"tmux-256color"
target key1C76 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7286,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 13,
        dir_type: 1,
        name: "tmux-256color",
    },
)
show hex data
76 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0D 00 01 74 6D 75 78 2D 32 35 36 63 6F 6C 6F 72 
1C24Dir (54)8E041903"tvi912b-unk-vb" @ 1C942598000
name"tvi912b-unk-vb"
target key1C94 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7316,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tvi912b-unk-vb",
    },
)
show hex data
94 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 76 69 39 31 32 62 2D 75 6E 6B 2D 76 62