Tree 5 (filesystem)

Explanation

This page shows the content of a tree. It is essentially a list of items, each of which consist of a key and a value.

The key is shown in the boxes on the left. It is a triple of a 64-bit id, an 8-bit type, and a 64-bit offset. What each of them means depends on the tree we're in. You can search for a key id by using the search field below.

The value is summarized to the right of the key. To see the value in more detail, unfold the key by clicking on it.

Finally, to the very right, we have the logical address of the metadata node which the item is stored in.

go back to root tree
1C24Dir (54)C7090605"tek4025a" @ 1C3D2598000
name"tek4025a"
target key1C3D Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7229,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 8,
        dir_type: 1,
        name: "tek4025a",
    },
)
show hex data
3D 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 08 00 01 74 65 6B 34 30 32 35 61 
1C24Dir (54)C7386424"tvi912c-unk-vb" @ 1C942598000
name"tvi912c-unk-vb"
target key1C94 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7316,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tvi912c-unk-vb",
    },
)
show hex data
94 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 76 69 39 31 32 63 2D 75 6E 6B 2D 76 62 
1C24Dir (54)C792C430"trs2" @ 1C792598000
name"trs2"
target key1C79 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7289,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 4,
        dir_type: 1,
        name: "trs2",
    },
)
show hex data
79 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 04 00 01 74 72 73 32 
1C24Dir (54)C9092633"tvi920b-2p-mc" @ 1C9A2598000
name"tvi920b-2p-mc"
target key1C9A Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7322,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 13,
        dir_type: 1,
        name: "tvi920b-2p-mc",
    },
)
show hex data
9A 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0D 00 01 74 76 69 39 32 30 62 2D 32 70 2D 6D 63 
1C24Dir (54)C9234EB8"tty43" @ 1C7F2598000
name"tty43"
target key1C7F Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7295,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "tty43",
    },
)
show hex data
7F 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 74 79 34 33 
1C24Dir (54)CA72F970"tvi912b+dim" @ 1C872598000
name"tvi912b+dim"
target key1C87 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7303,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 11,
        dir_type: 1,
        name: "tvi912b+dim",
    },
)
show hex data
87 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0B 00 01 74 76 69 39 31 32 62 2B 64 69 6D 
1C24Dir (54)CE23A827"tty4426" @ 17DB2598000
name"tty4426"
target key17DB Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 6107,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tty4426",
    },
)
show hex data
DB 17 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 74 79 34 34 32 36 
1C24Dir (54)CE506313"tvi955" @ 1CB02598000
name"tvi955"
target key1CB0 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7344,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 6,
        dir_type: 1,
        name: "tvi955",
    },
)
show hex data
B0 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 06 00 01 74 76 69 39 35 35 
1C24Dir (54)CEFC0943"tvi912b-unk-2p" @ 1C8E2598000
name"tvi912b-unk-2p"
target key1C8E Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7310,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tvi912b-unk-2p",
    },
)
show hex data
8E 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 76 69 39 31 32 62 2D 75 6E 6B 2D 32 70 
1C24Dir (54)CFCC4271"tty5420-w-rv-n" @ 17D12598000
name"tty5420-w-rv-n"
target key17D1 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 6097,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tty5420-w-rv-n",
    },
)
show hex data
D1 17 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 74 79 35 34 32 30 2D 77 2D 72 76 2D 6E 
1C24Dir (54)D333F13D"tvi912c-p-vb" @ 1C922598000
name"tvi912c-p-vb"
target key1C92 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7314,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi912c-p-vb",
    },
)
show hex data
92 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 31 32 63 2D 70 2D 76 62 
1C24Dir (54)D467CFE7"teleray" @ 1C262598000
name"teleray"
target key1C26 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7206,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "teleray",
    },
)
show hex data
26 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 6C 65 72 61 79 
1C24Dir (54)D6A2DBA8"tvi920b-p" @ 1C9F2598000
name"tvi920b-p"
target key1C9F Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7327,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 9,
        dir_type: 1,
        name: "tvi920b-p",
    },
)
show hex data
9F 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 09 00 01 74 76 69 39 32 30 62 2D 70 
1C24Dir (54)D6FD4469"tek4112" @ 1C432598000
name"tek4112"
target key1C43 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7235,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tek4112",
    },
)
show hex data
43 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 6B 34 31 31 32 
1C24Dir (54)D77C8852"tek" @ 1C312598000
name"tek"
target key1C31 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7217,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 3,
        dir_type: 1,
        name: "tek",
    },
)
show hex data
31 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 03 00 01 74 65 6B 
1C24Dir (54)D7F1B9E0"ti707" @ 1C642598000
name"ti707"
target key1C64 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7268,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "ti707",
    },
)
show hex data
64 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 69 37 30 37 
1C24Dir (54)D80E9C9A"tek4106brl" @ 1C412598000
name"tek4106brl"
target key1C41 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7233,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tek4106brl",
    },
)
show hex data
41 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 65 6B 34 31 30 36 62 72 6C 
1C24Dir (54)D8610D92"tek4404" @ 1C4E2598000
name"tek4404"
target key1C4E Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7246,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tek4404",
    },
)
show hex data
4E 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 6B 34 34 30 34 
1C24Dir (54)D8712FC4"tvi920c-p-vb" @ 1CA02598000
name"tvi920c-p-vb"
target key1CA0 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7328,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi920c-p-vb",
    },
)
show hex data
A0 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 32 30 63 2D 70 2D 76 62 
1C24Dir (54)DA457AAF"tek4014-sm" @ 1C342598000
name"tek4014-sm"
target key1C34 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7220,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tek4014-sm",
    },
)
show hex data
34 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 65 6B 34 30 31 34 2D 73 6D 
1C24Dir (54)DA73BD4C"tty40" @ 18DB2598000
name"tty40"
target key18DB Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 6363,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "tty40",
    },
)
show hex data
DB 18 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 74 79 34 30 
1C24Dir (54)DB8B35B4"tvi920c-mc-2p" @ 1C9A2598000
name"tvi920c-mc-2p"
target key1C9A Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7322,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 13,
        dir_type: 1,
        name: "tvi920c-mc-2p",
    },
)
show hex data
9A 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0D 00 01 74 76 69 39 32 30 63 2D 6D 63 2D 32 70 
1C24Dir (54)DC80906C"tvi920c-unk" @ 1CA12598000
name"tvi920c-unk"
target key1CA1 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7329,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 11,
        dir_type: 1,
        name: "tvi920c-unk",
    },
)
show hex data
A1 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0B 00 01 74 76 69 39 32 30 63 2D 75 6E 6B 
1C24Dir (54)DCE447E1"tvi970" @ 1CB12598000
name"tvi970"
target key1CB1 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7345,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 6,
        dir_type: 1,
        name: "tvi970",
    },
)
show hex data
B1 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 06 00 01 74 76 69 39 37 30 
1C24Dir (54)DF2D0A23"tab132-w-rv" @ 1C2F2598000
name"tab132-w-rv"
target key1C2F Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7215,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 11,
        dir_type: 1,
        name: "tab132-w-rv",
    },
)
show hex data
2F 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0B 00 01 74 61 62 31 33 32 2D 77 2D 72 76 
1C24Dir (54)DFD86A46"ti916" @ 1C662598000
name"ti916"
target key1C66 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7270,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "ti916",
    },
)
show hex data
66 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 69 39 31 36 
1C24Dir (54)E08467E6"tvi920b-vb-p" @ 1CA02598000
name"tvi920b-vb-p"
target key1CA0 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7328,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi920b-vb-p",
    },
)
show hex data
A0 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 32 30 62 2D 76 62 2D 70 
1C24Dir (54)E0FD4D6C"tvi920c-2p-p" @ 1C9B2598000
name"tvi920c-2p-p"
target key1C9B Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7323,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi920c-2p-p",
    },
)
show hex data
9B 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 32 30 63 2D 32 70 2D 70 
1C24Dir (54)E1443242"tab" @ 1C2C2598000
name"tab"
target key1C2C Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7212,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 3,
        dir_type: 1,
        name: "tab",
    },
)
show hex data
2C 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 03 00 01 74 61 62 
1C24Dir (54)E1B5F034"tvi912b-mc" @ 1C8F2598000
name"tvi912b-mc"
target key1C8F Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7311,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 10,
        dir_type: 1,
        name: "tvi912b-mc",
    },
)
show hex data
8F 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0A 00 01 74 76 69 39 31 32 62 2D 6D 63 
1C24Dir (54)E3074E96"terminology-0.6.1" @ 1C5F2598000
name"terminology-0.6.1"
target key1C5F Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7263,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 17,
        dir_type: 1,
        name: "terminology-0.6.1",
    },
)
show hex data
5F 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 11 00 01 74 65 72 6D 69 6E 6F 6C 6F 67 79 2D 30 2E 36 2E 31 
1C24Dir (54)E491FFC0"tvi920b-unk" @ 1CA12598000
name"tvi920b-unk"
target key1CA1 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7329,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 11,
        dir_type: 1,
        name: "tvi920b-unk",
    },
)
show hex data
A1 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0B 00 01 74 76 69 39 32 30 62 2D 75 6E 6B 
1C24Dir (54)E5F46752"teken-vt" @ 1C4F2598000
name"teken-vt"
target key1C4F Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7247,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 8,
        dir_type: 1,
        name: "teken-vt",
    },
)
show hex data
4F 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 08 00 01 74 65 6B 65 6E 2D 76 74 
1C24Dir (54)E67DD219"tvi912b-2p-unk" @ 1C8E2598000
name"tvi912b-2p-unk"
target key1C8E Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7310,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tvi912b-2p-unk",
    },
)
show hex data
8E 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 76 69 39 31 32 62 2D 32 70 2D 75 6E 6B 
1C24Dir (54)E8824FCF"tty4420" @ 17D42598000
name"tty4420"
target key17D4 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 6100,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tty4420",
    },
)
show hex data
D4 17 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 74 79 34 34 32 30 
1C24Dir (54)EB3FC2DF"ti926" @ 1C6E2598000
name"ti926"
target key1C6E Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7278,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "ti926",
    },
)
show hex data
6E 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 69 39 32 36 
1C24Dir (54)EBBF9395"tvi912c-2p-p" @ 1C8D2598000
name"tvi912c-2p-p"
target key1C8D Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7309,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi912c-2p-p",
    },
)
show hex data
8D 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 31 32 63 2D 32 70 2D 70 
1C24Dir (54)EBC6B91F"tvi912b-vb-p" @ 1C922598000
name"tvi912b-vb-p"
target key1C92 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7314,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 12,
        dir_type: 1,
        name: "tvi912b-vb-p",
    },
)
show hex data
92 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0C 00 01 74 76 69 39 31 32 62 2D 76 62 2D 70 
1C24Dir (54)ECB07D29"tvi912c-vb-unk" @ 1C942598000
name"tvi912c-vb-unk"
target key1C94 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7316,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 14,
        dir_type: 1,
        name: "tvi912c-vb-unk",
    },
)
show hex data
94 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0E 00 01 74 76 69 39 31 32 63 2D 76 62 2D 75 6E 6B 
1C24Dir (54)EDE30134"tek4025-17-ws" @ 1C3A2598000
name"tek4025-17-ws"
target key1C3A Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7226,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 13,
        dir_type: 1,
        name: "tek4025-17-ws",
    },
)
show hex data
3A 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0D 00 01 74 65 6B 34 30 32 35 2D 31 37 2D 77 73 
1C24Dir (54)EE03EB28"tws-generic" @ 19052598000
name"tws-generic"
target key1905 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 6405,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 11,
        dir_type: 1,
        name: "tws-generic",
    },
)
show hex data
05 19 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0B 00 01 74 77 73 2D 67 65 6E 65 72 69 63 
1C24Dir (54)F05CA381"tek4114" @ 1C432598000
name"tek4114"
target key1C43 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7235,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tek4114",
    },
)
show hex data
43 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 6B 34 31 31 34 
1C24Dir (54)F0AEC802"tek4107" @ 1C422598000
name"tek4107"
target key1C42 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7234,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 7,
        dir_type: 1,
        name: "tek4107",
    },
)
show hex data
42 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 07 00 01 74 65 6B 34 31 30 37 
1C24Dir (54)F370093C"tvi920b-mc-vb" @ 1C9E2598000
name"tvi920b-mc-vb"
target key1C9E Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7326,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 13,
        dir_type: 1,
        name: "tvi920b-mc-vb",
    },
)
show hex data
9E 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0D 00 01 74 76 69 39 32 30 62 2D 6D 63 2D 76 62 
1C24Dir (54)F39DF927"ts100-sp" @ 1C7A2598000
name"ts100-sp"
target key1C7A Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7290,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 8,
        dir_type: 1,
        name: "ts100-sp",
    },
)
show hex data
7A 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 08 00 01 74 73 31 30 30 2D 73 70 
1C24Dir (54)F41AD509"tvi950-rv" @ 1CAD2598000
name"tvi950-rv"
target key1CAD Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7341,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 9,
        dir_type: 1,
        name: "tvi950-rv",
    },
)
show hex data
AD 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 09 00 01 74 76 69 39 35 30 2D 72 76 
1C24Dir (54)F639B8D8"ts-1p" @ 194A2598000
name"ts-1p"
target key194A Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 6474,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 5,
        dir_type: 1,
        name: "ts-1p",
    },
)
show hex data
4A 19 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 05 00 01 74 73 2D 31 70 
1C24Dir (54)F836ED47"tab132" @ 1C2C2598000
name"tab132"
target key1C2C Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7212,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 6,
        dir_type: 1,
        name: "tab132",
    },
)
show hex data
2C 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 06 00 01 74 61 62 31 33 32 
1C24Dir (54)F8CC542E"terminology-1.0.0" @ 1C602598000
name"terminology-1.0.0"
target key1C60 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7264,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 17,
        dir_type: 1,
        name: "terminology-1.0.0",
    },
)
show hex data
60 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 11 00 01 74 65 72 6D 69 6E 6F 6C 6F 67 79 2D 31 2E 30 2E 30 
1C24Dir (54)FAE08D4C"teken-16color" @ 1C502598000
name"teken-16color"
target key1C50 Inode 0
show full value
Dir(
    DirItem {
        location: Key {
            key_id: 7248,
            key_type: Inode,
            key_offset: 0,
        },
        transid: 9,
        data_len: 0,
        name_len: 13,
        dir_type: 1,
        name: "teken-16color",
    },
)
show hex data
50 1C 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 00 00 0D 00 01 74 65 6B 65 6E 2D 31 36 63 6F 6C 6F 72