Tree 5 (filesystem)

Explanation

This page shows the content of a tree. It is essentially a list of items, each of which consist of a key and a value.

The key is shown in the boxes on the left. It is a triple of a 64-bit id, an 8-bit type, and a 64-bit offset. What each of them means depends on the tree we're in. You can search for a key id by using the search field below.

The value is summarized to the right of the key. To see the value in more detail, unfold the key by clicking on it.

Finally, to the very right, we have the logical address of the metadata node which the item is stored in.

go back to root tree
15B4ExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                112,
                95,
                102,
                117,
                110,
                99,
                115,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 70 5F 66 75 6E 63 73 2E 33 78 2E 67 7A 
15B5Inode (01)0symbolic link, mode 07772324000
size14
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 14,
        nbytes: 14,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 18,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 0E 00 00 00 00 00 00 00 0E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 12 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15B5Ref (0C)28C["scale_form.3x.gz"]2324000
name"scale_form.3x.gz"
index611
show full value
Ref(
    [
        RefItem {
            index: 611,
            name_len: 16,
            name: "scale_form.3x.gz",
        },
    ],
)
show hex data
63 02 00 00 00 00 00 00 10 00 73 63 61 6C 65 5F 66 6F 72 6D 2E 33 78 2E 67 7A 
15B5ExtentData (6C)0inline, length 14 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 14,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                102,
                111,
                114,
                109,
                95,
                119,
                105,
                110,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 0E 00 00 00 00 00 00 00 00 00 00 00 00 66 6F 72 6D 5F 77 69 6E 2E 33 78 2E 67 7A 
15B6Inode (01)0symbolic link, mode 07772324000
size14
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 14,
        nbytes: 14,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 18,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 0E 00 00 00 00 00 00 00 0E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 12 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15B6Ref (0C)28C["scale_menu.3x.gz"]2324000
name"scale_menu.3x.gz"
index612
show full value
Ref(
    [
        RefItem {
            index: 612,
            name_len: 16,
            name: "scale_menu.3x.gz",
        },
    ],
)
show hex data
64 02 00 00 00 00 00 00 10 00 73 63 61 6C 65 5F 6D 65 6E 75 2E 33 78 2E 67 7A 
15B6ExtentData (6C)0inline, length 14 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 14,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                109,
                101,
                110,
                117,
                95,
                119,
                105,
                110,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 0E 00 00 00 00 00 00 00 00 00 00 00 00 6D 65 6E 75 5F 77 69 6E 2E 33 78 2E 67 7A 
15B7Inode (01)0symbolic link, mode 07772324000
size16
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 16,
        nbytes: 16,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 29,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 10 00 00 00 00 00 00 00 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1D 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15B7Ref (0C)28C["scanw.3x.gz"]2324000
name"scanw.3x.gz"
index613
show full value
Ref(
    [
        RefItem {
            index: 613,
            name_len: 11,
            name: "scanw.3x.gz",
        },
    ],
)
show hex data
65 02 00 00 00 00 00 00 0B 00 73 63 61 6E 77 2E 33 78 2E 67 7A 
15B7ExtentData (6C)0inline, length 16 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 16,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                99,
                97,
                110,
                119,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 10 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 63 61 6E 77 2E 33 78 2E 67 7A 
15B8Inode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 17,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15B8Ref (0C)28C["scr_dump.3x.gz"]2324000
name"scr_dump.3x.gz"
index614
show full value
Ref(
    [
        RefItem {
            index: 614,
            name_len: 14,
            name: "scr_dump.3x.gz",
        },
    ],
)
show hex data
66 02 00 00 00 00 00 00 0E 00 73 63 72 5F 64 75 6D 70 2E 33 78 2E 67 7A 
15B8ExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                99,
                114,
                95,
                100,
                117,
                109,
                112,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 63 72 5F 64 75 6D 70 2E 33 78 2E 67 7A 
15B9Inode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 39,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 27 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15B9Ref (0C)28C["scr_init.3x.gz"]2324000
name"scr_init.3x.gz"
index615
show full value
Ref(
    [
        RefItem {
            index: 615,
            name_len: 14,
            name: "scr_init.3x.gz",
        },
    ],
)
show hex data
67 02 00 00 00 00 00 00 0E 00 73 63 72 5F 69 6E 69 74 2E 33 78 2E 67 7A 
15B9ExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                99,
                114,
                95,
                100,
                117,
                109,
                112,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 63 72 5F 64 75 6D 70 2E 33 78 2E 67 7A 
15BAInode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 39,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 27 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15BARef (0C)28C["scr_init_sp.3x.gz"]2324000
name"scr_init_sp.3x.gz"
index616
show full value
Ref(
    [
        RefItem {
            index: 616,
            name_len: 17,
            name: "scr_init_sp.3x.gz",
        },
    ],
)
show hex data
68 02 00 00 00 00 00 00 11 00 73 63 72 5F 69 6E 69 74 5F 73 70 2E 33 78 2E 67 7A 
15BAExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                112,
                95,
                102,
                117,
                110,
                99,
                115,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 70 5F 66 75 6E 63 73 2E 33 78 2E 67 7A 
15BBInode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 28,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1C 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15BBRef (0C)28C["scr_restore.3x.gz"]2324000
name"scr_restore.3x.gz"
index617
show full value
Ref(
    [
        RefItem {
            index: 617,
            name_len: 17,
            name: "scr_restore.3x.gz",
        },
    ],
)
show hex data
69 02 00 00 00 00 00 00 11 00 73 63 72 5F 72 65 73 74 6F 72 65 2E 33 78 2E 67 7A 
15BBExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                99,
                114,
                95,
                100,
                117,
                109,
                112,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 63 72 5F 64 75 6D 70 2E 33 78 2E 67 7A 
15BCInode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 98,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 62 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15BCRef (0C)28C["scr_restore_sp.3x.gz"]2324000
name"scr_restore_sp.3x.gz"
index618
show full value
Ref(
    [
        RefItem {
            index: 618,
            name_len: 20,
            name: "scr_restore_sp.3x.gz",
        },
    ],
)
show hex data
6A 02 00 00 00 00 00 00 14 00 73 63 72 5F 72 65 73 74 6F 72 65 5F 73 70 2E 33 78 2E 67 7A 
15BCExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                112,
                95,
                102,
                117,
                110,
                99,
                115,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 70 5F 66 75 6E 63 73 2E 33 78 2E 67 7A 
15BDInode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 150,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 96 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15BDRef (0C)28C["scr_set.3x.gz"]2324000
name"scr_set.3x.gz"
index619
show full value
Ref(
    [
        RefItem {
            index: 619,
            name_len: 13,
            name: "scr_set.3x.gz",
        },
    ],
)
show hex data
6B 02 00 00 00 00 00 00 0D 00 73 63 72 5F 73 65 74 2E 33 78 2E 67 7A 
15BDExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                99,
                114,
                95,
                100,
                117,
                109,
                112,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 63 72 5F 64 75 6D 70 2E 33 78 2E 67 7A 
15BEInode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 105,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 69 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15BERef (0C)28C["scr_set_sp.3x.gz"]2324000
name"scr_set_sp.3x.gz"
index620
show full value
Ref(
    [
        RefItem {
            index: 620,
            name_len: 16,
            name: "scr_set_sp.3x.gz",
        },
    ],
)
show hex data
6C 02 00 00 00 00 00 00 10 00 73 63 72 5F 73 65 74 5F 73 70 2E 33 78 2E 67 7A 
15BEExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                112,
                95,
                102,
                117,
                110,
                99,
                115,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 70 5F 66 75 6E 63 73 2E 33 78 2E 67 7A 
15BFInode (01)0symbolic link, mode 07772324000
size17
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 17,
        nbytes: 17,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 22,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 11 00 00 00 00 00 00 00 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15BFRef (0C)28C["scrl.3x.gz"]2324000
name"scrl.3x.gz"
index621
show full value
Ref(
    [
        RefItem {
            index: 621,
            name_len: 10,
            name: "scrl.3x.gz",
        },
    ],
)
show hex data
6D 02 00 00 00 00 00 00 0A 00 73 63 72 6C 2E 33 78 2E 67 7A 
15BFExtentData (6C)0inline, length 17 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 17,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                99,
                114,
                111,
                108,
                108,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 11 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 63 72 6F 6C 6C 2E 33 78 2E 67 7A 
15C0Inode (01)0symbolic link, mode 07772324000
size17
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 17,
        nbytes: 17,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 109,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 11 00 00 00 00 00 00 00 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 6D 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15C0Ref (0C)28C["scroll.3x.gz"]2324000
name"scroll.3x.gz"
index622
show full value
Ref(
    [
        RefItem {
            index: 622,
            name_len: 12,
            name: "scroll.3x.gz",
        },
    ],
)
show hex data
6E 02 00 00 00 00 00 00 0C 00 73 63 72 6F 6C 6C 2E 33 78 2E 67 7A 
15C0ExtentData (6C)0inline, length 17 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 17,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                115,
                99,
                114,
                111,
                108,
                108,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 11 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 73 63 72 6F 6C 6C 2E 33 78 2E 67 7A 
15C1Inode (01)0symbolic link, mode 07772324000
size18
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 18,
        nbytes: 18,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 821,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 12 00 00 00 00 00 00 00 12 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 35 03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15C1Ref (0C)28C["scrollok.3x.gz"]2324000
name"scrollok.3x.gz"
index623
show full value
Ref(
    [
        RefItem {
            index: 623,
            name_len: 14,
            name: "scrollok.3x.gz",
        },
    ],
)
show hex data
6F 02 00 00 00 00 00 00 0E 00 73 63 72 6F 6C 6C 6F 6B 2E 33 78 2E 67 7A 
15C1ExtentData (6C)0inline, length 18 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 18,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                111,
                117,
                116,
                111,
                112,
                116,
                115,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 12 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 6F 75 74 6F 70 74 73 2E 33 78 2E 67 7A 
15C2Inode (01)0symbolic link, mode 07772324000
size15
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 15,
        nbytes: 15,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 59,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 0F 00 00 00 00 00 00 00 0F 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 3B 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15C2Ref (0C)28C["set_current_field.3x.gz"]2324000
name"set_current_field.3x.gz"
index624
show full value
Ref(
    [
        RefItem {
            index: 624,
            name_len: 23,
            name: "set_current_field.3x.gz",
        },
    ],
)
show hex data
70 02 00 00 00 00 00 00 17 00 73 65 74 5F 63 75 72 72 65 6E 74 5F 66 69 65 6C 64 2E 33 78 2E 67 7A 
15C2ExtentData (6C)0inline, length 15 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 15,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                102,
                111,
                114,
                109,
                95,
                112,
                97,
                103,
                101,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 0F 00 00 00 00 00 00 00 00 00 00 00 00 66 6F 72 6D 5F 70 61 67 65 2E 33 78 2E 67 7A 
15C3Inode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 38,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 26 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15C3Ref (0C)28C["set_current_item.3x.gz"]2324000
name"set_current_item.3x.gz"
index625
show full value
Ref(
    [
        RefItem {
            index: 625,
            name_len: 22,
            name: "set_current_item.3x.gz",
        },
    ],
)
show hex data
71 02 00 00 00 00 00 00 16 00 73 65 74 5F 63 75 72 72 65 6E 74 5F 69 74 65 6D 2E 33 78 2E 67 7A 
15C3ExtentData (6C)0inline, length 19 B2324000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                109,
                105,
                116,
                101,
                109,
                95,
                99,
                117,
                114,
                114,
                101,
                110,
                116,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 6D 69 74 65 6D 5F 63 75 72 72 65 6E 74 2E 33 78 2E 67 7A 
15C4Inode (01)0symbolic link, mode 07772324000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 40,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 28 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A 
15C4Ref (0C)28C["set_curterm.3x.gz"]237C000
name"set_curterm.3x.gz"
index626
show full value
Ref(
    [
        RefItem {
            index: 626,
            name_len: 17,
            name: "set_curterm.3x.gz",
        },
    ],
)
show hex data
72 02 00 00 00 00 00 00 11 00 73 65 74 5F 63 75 72 74 65 72 6D 2E 33 78 2E 67 7A 
15C4ExtentData (6C)0inline, length 19 B237C000
show full value
ExtentData(
    ExtentDataItem {
        header: ExtentDataHeader {
            generation: 9,
            ram_bytes: 19,
            compression: 0,
            encryption: 0,
            other_encoding: 0,
            extent_type: 0,
        },
        data: Inline(
            [
                99,
                117,
                114,
                115,
                95,
                116,
                101,
                114,
                109,
                105,
                110,
                102,
                111,
                46,
                51,
                120,
                46,
                103,
                122,
            ],
        ),
    },
)
show hex data
09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 63 75 72 73 5F 74 65 72 6D 69 6E 66 6F 2E 33 78 2E 67 7A 
15C5Inode (01)0symbolic link, mode 0777237C000
size19
mode41471
uid0
gid0
nlink1
atime1708913572
ctime1708913572
mtime1684872158
otime1708913572
show full value
Inode(
    InodeItem {
        generation: 9,
        transid: 9,
        size: 19,
        nbytes: 19,
        block_group: 0,
        nlink: 1,
        uid: 0,
        gid: 0,
        mode: 41471,
        rdev: 0,
        flags: 0,
        sequence: 5,
        atime: Time {
            sec: 1708913572,
            nsec: 0,
        },
        ctime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
        mtime: Time {
            sec: 1684872158,
            nsec: 0,
        },
        otime: Time {
            sec: 1708913572,
            nsec: 444178328,
        },
    },
)
show hex data
09 00 00 00 00 00 00 00 09 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 FF A1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 05 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A DE 1B 6D 64 00 00 00 00 00 00 00 00 A4 F3 DB 65 00 00 00 00 98 9F 79 1A