This page shows the content of a tree. It is essentially a list of items, each of which consist of a key and a value.
The key is shown in the boxes on the left. It is a triple of a 64-bit id, an 8-bit type, and a 64-bit offset. What each of them means depends on the tree we're in. You can search for a key id by using the search field below.
The value is summarized to the right of the key. To see the value in more detail, unfold the key by clicking on it.
Finally, to the very right, we have the logical address of the metadata node which the item is stored in.
| size | 26 |
| mode | 16877 |
| uid | 0 |
| gid | 0 |
| nlink | 1 |
| atime | 1708913586 |
| ctime | 1708913584 |
| mtime | 1708913584 |
| otime | 1708913584 |
Inode(
InodeItem {
generation: 10,
transid: 10,
size: 26,
nbytes: 0,
block_group: 0,
nlink: 1,
uid: 0,
gid: 0,
mode: 16877,
rdev: 0,
flags: 0,
sequence: 4,
atime: Time {
sec: 1708913586,
nsec: 797598177,
},
ctime: Time {
sec: 1708913584,
nsec: 957587075,
},
mtime: Time {
sec: 1708913584,
nsec: 957587075,
},
otime: Time {
sec: 1708913584,
nsec: 957587075,
},
},
)0A 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 1A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 ED 41 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 B2 F3 DB 65 00 00 00 00 E1 61 8A 2F B0 F3 DB 65 00 00 00 00 83 9E 13 39 B0 F3 DB 65 00 00 00 00 83 9E 13 39 B0 F3 DB 65 00 00 00 00 83 9E 13 39
| name | "amdtee" |
| index | 2 |
Ref(
[
RefItem {
index: 2,
name_len: 6,
name: "amdtee",
},
],
)02 00 00 00 00 00 00 00 06 00 61 6D 64 74 65 65
| name | "amdtee.ko.zst" |
| target key | 83CF Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33743,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 13,
dir_type: 1,
name: "amdtee.ko.zst",
},
)CF 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 0D 00 01 61 6D 64 74 65 65 2E 6B 6F 2E 7A 73 74
| name | "amdtee.ko.zst" |
| target key | 83CF Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33743,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 13,
dir_type: 1,
name: "amdtee.ko.zst",
},
)CF 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 0D 00 01 61 6D 64 74 65 65 2E 6B 6F 2E 7A 73 74
| size | 13853 |
| mode | 33188 |
| uid | 0 |
| gid | 0 |
| nlink | 1 |
| atime | 1708913587 |
| ctime | 1708913584 |
| mtime | 1708705908 |
| otime | 1708913584 |
Inode(
InodeItem {
generation: 10,
transid: 10,
size: 13853,
nbytes: 16384,
block_group: 0,
nlink: 1,
uid: 0,
gid: 0,
mode: 33188,
rdev: 0,
flags: 0,
sequence: 3,
atime: Time {
sec: 1708913587,
nsec: 744270557,
},
ctime: Time {
sec: 1708913584,
nsec: 957587075,
},
mtime: Time {
sec: 1708705908,
nsec: 0,
},
otime: Time {
sec: 1708913584,
nsec: 957587075,
},
},
)0A 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 1D 36 00 00 00 00 00 00 00 40 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 A4 81 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 B3 F3 DB 65 00 00 00 00 DD AA 5C 2C B0 F3 DB 65 00 00 00 00 83 9E 13 39 74 C8 D8 65 00 00 00 00 00 00 00 00 B0 F3 DB 65 00 00 00 00 83 9E 13 39
| name | "amdtee.ko.zst" |
| index | 2 |
Ref(
[
RefItem {
index: 2,
name_len: 13,
name: "amdtee.ko.zst",
},
],
)02 00 00 00 00 00 00 00 0D 00 61 6D 64 74 65 65 2E 6B 6F 2E 7A 73 74
16 KiB on disk, starting at offset 0 within the extent at address 5A83C000; 16 KiB in the file starting from offset 0.
| compression | 0 |
| encryption | 0 |
| other_encoding | 0 |
ExtentData(
ExtentDataItem {
header: ExtentDataHeader {
generation: 10,
ram_bytes: 16384,
compression: 0,
encryption: 0,
other_encoding: 0,
extent_type: 1,
},
data: External(
ExternalExtent {
disk_bytenr: 1518583808,
disk_num_bytes: 16384,
offset: 0,
num_bytes: 16384,
},
),
},
)0A 00 00 00 00 00 00 00 00 40 00 00 00 00 00 00 00 00 00 00 01 00 C0 83 5A 00 00 00 00 00 40 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 40 00 00 00 00 00 00
| size | 17559 |
| mode | 33188 |
| uid | 0 |
| gid | 0 |
| nlink | 1 |
| atime | 1708913587 |
| ctime | 1708913584 |
| mtime | 1708705908 |
| otime | 1708913584 |
Inode(
InodeItem {
generation: 10,
transid: 10,
size: 17559,
nbytes: 20480,
block_group: 0,
nlink: 1,
uid: 0,
gid: 0,
mode: 33188,
rdev: 0,
flags: 0,
sequence: 3,
atime: Time {
sec: 1708913587,
nsec: 744270557,
},
ctime: Time {
sec: 1708913584,
nsec: 957587075,
},
mtime: Time {
sec: 1708705908,
nsec: 0,
},
otime: Time {
sec: 1708913584,
nsec: 957587075,
},
},
)0A 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 97 44 00 00 00 00 00 00 00 50 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 A4 81 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 B3 F3 DB 65 00 00 00 00 DD AA 5C 2C B0 F3 DB 65 00 00 00 00 83 9E 13 39 74 C8 D8 65 00 00 00 00 00 00 00 00 B0 F3 DB 65 00 00 00 00 83 9E 13 39
| name | "tee.ko.zst" |
| index | 3 |
Ref(
[
RefItem {
index: 3,
name_len: 10,
name: "tee.ko.zst",
},
],
)03 00 00 00 00 00 00 00 0A 00 74 65 65 2E 6B 6F 2E 7A 73 74
20 KiB on disk, starting at offset 0 within the extent at address 5A840000; 20 KiB in the file starting from offset 0.
| compression | 0 |
| encryption | 0 |
| other_encoding | 0 |
ExtentData(
ExtentDataItem {
header: ExtentDataHeader {
generation: 10,
ram_bytes: 20480,
compression: 0,
encryption: 0,
other_encoding: 0,
extent_type: 1,
},
data: External(
ExternalExtent {
disk_bytenr: 1518600192,
disk_num_bytes: 20480,
offset: 0,
num_bytes: 20480,
},
),
},
)0A 00 00 00 00 00 00 00 00 50 00 00 00 00 00 00 00 00 00 00 01 00 00 84 5A 00 00 00 00 00 50 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 50 00 00 00 00 00 00
| size | 62 |
| mode | 16877 |
| uid | 0 |
| gid | 0 |
| nlink | 1 |
| atime | 1708913586 |
| ctime | 1708913584 |
| mtime | 1708913584 |
| otime | 1708913584 |
Inode(
InodeItem {
generation: 10,
transid: 10,
size: 62,
nbytes: 0,
block_group: 0,
nlink: 1,
uid: 0,
gid: 0,
mode: 16877,
rdev: 0,
flags: 0,
sequence: 5,
atime: Time {
sec: 1708913586,
nsec: 797598177,
},
ctime: Time {
sec: 1708913584,
nsec: 957587075,
},
mtime: Time {
sec: 1708913584,
nsec: 957587075,
},
otime: Time {
sec: 1708913584,
nsec: 957587075,
},
},
)0A 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 3E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 ED 41 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 05 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 B2 F3 DB 65 00 00 00 00 E1 61 8A 2F B0 F3 DB 65 00 00 00 00 83 9E 13 39 B0 F3 DB 65 00 00 00 00 83 9E 13 39 B0 F3 DB 65 00 00 00 00 83 9E 13 39
| name | "thermal" |
| index | 91 |
Ref(
[
RefItem {
index: 91,
name_len: 7,
name: "thermal",
},
],
)5B 00 00 00 00 00 00 00 07 00 74 68 65 72 6D 61 6C
| name | "intel" |
| target key | 83D2 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33746,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 5,
dir_type: 2,
name: "intel",
},
)D2 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 05 00 02 69 6E 74 65 6C
| name | "thermal-generic-adc.ko.zst" |
| target key | 83EB Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33771,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 26,
dir_type: 1,
name: "thermal-generic-adc.ko.zst",
},
)EB 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1A 00 01 74 68 65 72 6D 61 6C 2D 67 65 6E 65 72 69 63 2D 61 64 63 2E 6B 6F 2E 7A 73 74
| name | "intel" |
| target key | 83D2 Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33746,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 5,
dir_type: 2,
name: "intel",
},
)D2 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 05 00 02 69 6E 74 65 6C
| name | "thermal-generic-adc.ko.zst" |
| target key | 83EB Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33771,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 26,
dir_type: 1,
name: "thermal-generic-adc.ko.zst",
},
)EB 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1A 00 01 74 68 65 72 6D 61 6C 2D 67 65 6E 65 72 69 63 2D 61 64 63 2E 6B 6F 2E 7A 73 74
| size | 390 |
| mode | 16877 |
| uid | 0 |
| gid | 0 |
| nlink | 1 |
| atime | 1708913586 |
| ctime | 1708913584 |
| mtime | 1708913584 |
| otime | 1708913584 |
Inode(
InodeItem {
generation: 10,
transid: 10,
size: 390,
nbytes: 0,
block_group: 0,
nlink: 1,
uid: 0,
gid: 0,
mode: 16877,
rdev: 0,
flags: 0,
sequence: 11,
atime: Time {
sec: 1708913586,
nsec: 797598177,
},
ctime: Time {
sec: 1708913584,
nsec: 957587075,
},
mtime: Time {
sec: 1708913584,
nsec: 957587075,
},
otime: Time {
sec: 1708913584,
nsec: 957587075,
},
},
)0A 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 86 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 ED 41 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0B 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 B2 F3 DB 65 00 00 00 00 E1 61 8A 2F B0 F3 DB 65 00 00 00 00 83 9E 13 39 B0 F3 DB 65 00 00 00 00 83 9E 13 39 B0 F3 DB 65 00 00 00 00 83 9E 13 39
| name | "intel" |
| index | 2 |
Ref(
[
RefItem {
index: 2,
name_len: 5,
name: "intel",
},
],
)02 00 00 00 00 00 00 00 05 00 69 6E 74 65 6C
| name | "intel_soc_dts_thermal.ko.zst" |
| target key | 83E8 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33768,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 28,
dir_type: 1,
name: "intel_soc_dts_thermal.ko.zst",
},
)E8 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1C 00 01 69 6E 74 65 6C 5F 73 6F 63 5F 64 74 73 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "intel_soc_dts_iosf.ko.zst" |
| target key | 83E7 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33767,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 25,
dir_type: 1,
name: "intel_soc_dts_iosf.ko.zst",
},
)E7 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 19 00 01 69 6E 74 65 6C 5F 73 6F 63 5F 64 74 73 5F 69 6F 73 66 2E 6B 6F 2E 7A 73 74
| name | "intel_bxt_pmic_thermal.ko.zst" |
| target key | 83E4 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33764,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 29,
dir_type: 1,
name: "intel_bxt_pmic_thermal.ko.zst",
},
)E4 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1D 00 01 69 6E 74 65 6C 5F 62 78 74 5F 70 6D 69 63 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "x86_pkg_temp_thermal.ko.zst" |
| target key | 83EA Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33770,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 27,
dir_type: 1,
name: "x86_pkg_temp_thermal.ko.zst",
},
)EA 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1B 00 01 78 38 36 5F 70 6B 67 5F 74 65 6D 70 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "intel_pch_thermal.ko.zst" |
| target key | 83E5 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33765,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 24,
dir_type: 1,
name: "intel_pch_thermal.ko.zst",
},
)E5 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 18 00 01 69 6E 74 65 6C 5F 70 63 68 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "intel_tcc_cooling.ko.zst" |
| target key | 83E9 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33769,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 24,
dir_type: 1,
name: "intel_tcc_cooling.ko.zst",
},
)E9 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 18 00 01 69 6E 74 65 6C 5F 74 63 63 5F 63 6F 6F 6C 69 6E 67 2E 6B 6F 2E 7A 73 74
| name | "int340x_thermal" |
| target key | 83D3 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33747,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 15,
dir_type: 2,
name: "int340x_thermal",
},
)D3 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 0F 00 02 69 6E 74 33 34 30 78 5F 74 68 65 72 6D 61 6C
| name | "intel_powerclamp.ko.zst" |
| target key | 83E6 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33766,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 23,
dir_type: 1,
name: "intel_powerclamp.ko.zst",
},
)E6 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 17 00 01 69 6E 74 65 6C 5F 70 6F 77 65 72 63 6C 61 6D 70 2E 6B 6F 2E 7A 73 74
| name | "int340x_thermal" |
| target key | 83D3 Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33747,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 15,
dir_type: 2,
name: "int340x_thermal",
},
)D3 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 0F 00 02 69 6E 74 33 34 30 78 5F 74 68 65 72 6D 61 6C
| name | "intel_bxt_pmic_thermal.ko.zst" |
| target key | 83E4 Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33764,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 29,
dir_type: 1,
name: "intel_bxt_pmic_thermal.ko.zst",
},
)E4 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1D 00 01 69 6E 74 65 6C 5F 62 78 74 5F 70 6D 69 63 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "intel_pch_thermal.ko.zst" |
| target key | 83E5 Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33765,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 24,
dir_type: 1,
name: "intel_pch_thermal.ko.zst",
},
)E5 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 18 00 01 69 6E 74 65 6C 5F 70 63 68 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "intel_powerclamp.ko.zst" |
| target key | 83E6 Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33766,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 23,
dir_type: 1,
name: "intel_powerclamp.ko.zst",
},
)E6 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 17 00 01 69 6E 74 65 6C 5F 70 6F 77 65 72 63 6C 61 6D 70 2E 6B 6F 2E 7A 73 74
| name | "intel_soc_dts_iosf.ko.zst" |
| target key | 83E7 Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33767,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 25,
dir_type: 1,
name: "intel_soc_dts_iosf.ko.zst",
},
)E7 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 19 00 01 69 6E 74 65 6C 5F 73 6F 63 5F 64 74 73 5F 69 6F 73 66 2E 6B 6F 2E 7A 73 74
| name | "intel_soc_dts_thermal.ko.zst" |
| target key | 83E8 Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33768,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 28,
dir_type: 1,
name: "intel_soc_dts_thermal.ko.zst",
},
)E8 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1C 00 01 69 6E 74 65 6C 5F 73 6F 63 5F 64 74 73 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "intel_tcc_cooling.ko.zst" |
| target key | 83E9 Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33769,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 24,
dir_type: 1,
name: "intel_tcc_cooling.ko.zst",
},
)E9 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 18 00 01 69 6E 74 65 6C 5F 74 63 63 5F 63 6F 6F 6C 69 6E 67 2E 6B 6F 2E 7A 73 74
| name | "x86_pkg_temp_thermal.ko.zst" |
| target key | 83EA Inode 0 |
DirIndex(
DirItem {
location: Key {
key_id: 33770,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 27,
dir_type: 1,
name: "x86_pkg_temp_thermal.ko.zst",
},
)EA 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1B 00 01 78 38 36 5F 70 6B 67 5F 74 65 6D 70 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| size | 908 |
| mode | 16877 |
| uid | 0 |
| gid | 0 |
| nlink | 1 |
| atime | 1708913586 |
| ctime | 1708913584 |
| mtime | 1708913584 |
| otime | 1708913584 |
Inode(
InodeItem {
generation: 10,
transid: 10,
size: 908,
nbytes: 0,
block_group: 0,
nlink: 1,
uid: 0,
gid: 0,
mode: 16877,
rdev: 0,
flags: 0,
sequence: 19,
atime: Time {
sec: 1708913586,
nsec: 797598177,
},
ctime: Time {
sec: 1708913584,
nsec: 957587075,
},
mtime: Time {
sec: 1708913584,
nsec: 957587075,
},
otime: Time {
sec: 1708913584,
nsec: 957587075,
},
},
)0A 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 8C 03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 ED 41 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 B2 F3 DB 65 00 00 00 00 E1 61 8A 2F B0 F3 DB 65 00 00 00 00 83 9E 13 39 B0 F3 DB 65 00 00 00 00 83 9E 13 39 B0 F3 DB 65 00 00 00 00 83 9E 13 39
| name | "int340x_thermal" |
| index | 2 |
Ref(
[
RefItem {
index: 2,
name_len: 15,
name: "int340x_thermal",
},
],
)02 00 00 00 00 00 00 00 0F 00 69 6E 74 33 34 30 78 5F 74 68 65 72 6D 61 6C
| name | "int3406_thermal.ko.zst" |
| target key | 83D9 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33753,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 22,
dir_type: 1,
name: "int3406_thermal.ko.zst",
},
)D9 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 16 00 01 69 6E 74 33 34 30 36 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "processor_thermal_device_pci.ko.zst" |
| target key | 83DC Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33756,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 35,
dir_type: 1,
name: "processor_thermal_device_pci.ko.zst",
},
)DC 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 23 00 01 70 72 6F 63 65 73 73 6F 72 5F 74 68 65 72 6D 61 6C 5F 64 65 76 69 63 65 5F 70 63 69 2E 6B 6F 2E 7A 73 74
| name | "int3403_thermal.ko.zst" |
| target key | 83D8 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33752,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 22,
dir_type: 1,
name: "int3403_thermal.ko.zst",
},
)D8 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 16 00 01 69 6E 74 33 34 30 33 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "processor_thermal_device.ko.zst" |
| target key | 83DB Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33755,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 31,
dir_type: 1,
name: "processor_thermal_device.ko.zst",
},
)DB 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1F 00 01 70 72 6F 63 65 73 73 6F 72 5F 74 68 65 72 6D 61 6C 5F 64 65 76 69 63 65 2E 6B 6F 2E 7A 73 74
| name | "int3400_thermal.ko.zst" |
| target key | 83D5 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33749,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 22,
dir_type: 1,
name: "int3400_thermal.ko.zst",
},
)D5 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 16 00 01 69 6E 74 33 34 30 30 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "processor_thermal_mbox.ko.zst" |
| target key | 83DE Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33758,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 29,
dir_type: 1,
name: "processor_thermal_mbox.ko.zst",
},
)DE 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1D 00 01 70 72 6F 63 65 73 73 6F 72 5F 74 68 65 72 6D 61 6C 5F 6D 62 6F 78 2E 6B 6F 2E 7A 73 74
| name | "processor_thermal_device_pci_legacy.ko.zst" |
| target key | 83DD Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33757,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 42,
dir_type: 1,
name: "processor_thermal_device_pci_legacy.ko.zst",
},
)DD 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 2A 00 01 70 72 6F 63 65 73 73 6F 72 5F 74 68 65 72 6D 61 6C 5F 64 65 76 69 63 65 5F 70 63 69 5F 6C 65 67 61 63 79 2E 6B 6F 2E 7A 73 74
| name | "int340x_thermal_zone.ko.zst" |
| target key | 83DA Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33754,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 27,
dir_type: 1,
name: "int340x_thermal_zone.ko.zst",
},
)DA 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1B 00 01 69 6E 74 33 34 30 78 5F 74 68 65 72 6D 61 6C 5F 7A 6F 6E 65 2E 6B 6F 2E 7A 73 74
| name | "processor_thermal_rfim.ko.zst" |
| target key | 83E1 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33761,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 29,
dir_type: 1,
name: "processor_thermal_rfim.ko.zst",
},
)E1 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1D 00 01 70 72 6F 63 65 73 73 6F 72 5F 74 68 65 72 6D 61 6C 5F 72 66 69 6D 2E 6B 6F 2E 7A 73 74
| name | "processor_thermal_power_floor.ko.zst" |
| target key | 83DF Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33759,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 36,
dir_type: 1,
name: "processor_thermal_power_floor.ko.zst",
},
)DF 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 24 00 01 70 72 6F 63 65 73 73 6F 72 5F 74 68 65 72 6D 61 6C 5F 70 6F 77 65 72 5F 66 6C 6F 6F 72 2E 6B 6F 2E 7A 73 74
| name | "processor_thermal_rapl.ko.zst" |
| target key | 83E0 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33760,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 29,
dir_type: 1,
name: "processor_thermal_rapl.ko.zst",
},
)E0 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1D 00 01 70 72 6F 63 65 73 73 6F 72 5F 74 68 65 72 6D 61 6C 5F 72 61 70 6C 2E 6B 6F 2E 7A 73 74
| name | "processor_thermal_wt_req.ko.zst" |
| target key | 83E3 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33763,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 31,
dir_type: 1,
name: "processor_thermal_wt_req.ko.zst",
},
)E3 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 1F 00 01 70 72 6F 63 65 73 73 6F 72 5F 74 68 65 72 6D 61 6C 5F 77 74 5F 72 65 71 2E 6B 6F 2E 7A 73 74
| name | "int3401_thermal.ko.zst" |
| target key | 83D6 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33750,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 22,
dir_type: 1,
name: "int3401_thermal.ko.zst",
},
)D6 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 16 00 01 69 6E 74 33 34 30 31 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74
| name | "int3402_thermal.ko.zst" |
| target key | 83D7 Inode 0 |
Dir(
DirItem {
location: Key {
key_id: 33751,
key_type: Inode,
key_offset: 0,
},
transid: 10,
data_len: 0,
name_len: 22,
dir_type: 1,
name: "int3402_thermal.ko.zst",
},
)D7 83 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 16 00 01 69 6E 74 33 34 30 32 5F 74 68 65 72 6D 61 6C 2E 6B 6F 2E 7A 73 74